Asianic is now an FDAS Solutions Provider
Asianic FDAS solutions provider Metro Manila, Philippines, Asianic FDAS solutions provider Manila, Asianic FDAS solutions Philippines, Asianic FDAS provider Manila, Asianic FDAS provider Metro Manila, Asianic FDAS provider Philippines. Asianic FDAS Manila, Asianic FDAS Metro Manila, Asianic FDAS Philippines. Asianic Fire Detection and Alarm Manila, Asianic Fire Detection and Alarm Metro Manila, Asianic Fire Detection and Alarm Philippines. Asianic FDAS. Fire Alarms, Manila, Fire Alarms Metro Manila, Fire Alarms, Philippines.
Design and installation of a fire detection system can often be a complex
process, with each project often bringing its own challenges in making sure the
system is compliant, reliable and easy to operate. Our team of engineers will
partner with your project management team using our expertise to meet the
specific requirements of your project.
Conventional systems
The philosophy of a conventional system revolves around
dividing the building into a number of areas called zones. The
detectors and call points within each zone are then wired on a
dedicated separate circuit.
In the event of a detector or call point being triggered, the
panel is able to identify which circuit contains the triggered
device and thereby indicate which zone the fire alarm has come
from. The indicated zone can then be manually searched to
locate the triggered device.
With this type of functionality a conventional system is best
used in smaller builds where it wouldn’t be difficult to locate
the triggered device in a given zone.
Addressable systems
Intelligent addressable systems overcome the limitations of
conventional systems as each fire detecting sensor or call point
is electronically coded with a unique identification or 'address'
which is programmed into the device during installation.
By using each devices' unique address, the control panel
is able to conduct two way communication with any of the
addressable devices connected to the system.
Under normal conditions the control panel continuously
interrogates each device in sequence and analyses the reply
to determine the status of each sensor or call point. The panel
checks whether each device is functioning correctly and also
the amount of smoke or heat that the device is currently
sensing.
With the functionality of being able to pinpoint exactly which
device is being triggered in an alarm or for a fault, addressable
systems are perfect for mid to large size builds with multiple
rooms and floors.
For more inquiries regarding Asianic FDAS (Asianic Fire detection and alarm systems) solutions, please email us onlinesales@asianic.com.ph or via our online contact form >>> http://asianic.com.ph/contact.php
You may also call us at : 709-2430 (Jay); 713-1469 (Elvert) and 470-7942 (Kristine)